<br class="iwlinks"/>[[en:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[bs:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[zh-cn:采用户用换热机组系统的热源能力的确定|采用户用换热机组系统的热源能力的确定]][[cs:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[da:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[et:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[es:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[fi:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[fr:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[hr:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[hu:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[fa:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[lv:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[nl:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[nb:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[sv:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[sl:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[sk:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[tr:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]][[sr-el:Heat source dimensioning for installations with flat stations|Heat source dimensioning for installations with flat stations]]

Wersja z 15:59, 8 lut 2022

Produkt InstalSystem 5
Typ artykułu PORADA I WSKAZÓWKA
Ostatnia aktualizacja 2019-11-13


Opis problemu

Sugeruje się, aby dobór mocy źródła ciepła skonsultować każdorazowo z producentem stacji mieszkaniowych. W razie braku szczegółowych wytycznych zaleca się zastosowanie jednego z poniższych rozwiązań.

Sposób rozwiązania

  • Jeśli w ramach źródła ciepła brak zbiornika buforowego - wtedy do wymiarowania źródła ciepła należy przyjąć wartość Moc całkowita.
    1. Moc całkowita.

  • Jeśli w ramach źródła ciepła uwzględniany jest zbiornik buforowy - podawana przez program wartość Moc całkowita jest mocą szczytową jaką ma zapewnić w instalacji zbiornik buforowy. Natomiast samo źródło ciepła sugeruje się wymiarować na sumę projektowego obciążenia cieplnego budynku (lub w razie braku obliczeń normowych, sumę obciążeń cieplnych pomieszczeń) z uwzględnieniem niewykorzystanych strat ciepła działek i niewykorzystanych strat ciepła ogrzewań płaszczyznowych (na zewnątrz budynku).
    2. Projektowe obciążenie cieplne budynku.


    3. Suma obciążeń cieplnych pomieszczeń.


    4. Straty ciepła działek, straty ciepła ogrzewań płaszczyznowych.